top of page
Product code:
4650
AC insulation bolt
|
Features / Specifications
Type
For general-purpose use
PVdF lining type
Product information
The PVdF insulation lining of the bolt exhibits excellent insulation characteristic, and stable corrosion resistance and weather resistance. FRP is used for the insulation washer, and a set of insulation bolt and gasket are used to prevent corrosion. With general insulation sleeve type gaskets, setup can be difficult if flange misalignment occurs. However, with the PILLAR insulation bolt, setup is easy because the insulation lining has the same diameter as the effective diameter of the thread.
Main constituent
materials
Bolt, insulation lining (PVdF), insulation washer, hexagon nut, and plain washer
Main applications
Various pipes and connecting parts requiring insulation
Specifications
Temperature: -60 to +120°C
Specific volume resistance: 0.5×10^14Ω・ cm
Dielectric strength: 10 kV/mm or more
Product category
Insulation bolts & gaskets
bottom of page